DVM S, Standard, Heat Recovery R410a, 380~415V, 50Hz, 3Ф, Outdoor Unit

DVM S, Standard, Heat Recovery R410a, 380~415V, 50Hz, 3Ф, Outdoor Unit

AM160FXVAGR/EU

  • Reduce expenses with installation designed to be easy and flexible
  • Achieve high energy efficiency with the DSI system
  • Discover and fix problems readily with Auto Commissioning Management (ACM)

Choose your Capacity

DVM S, Standard, Heat Recovery R410a, 380~415V, 50Hz, 3Ф, Outdoor Unit

16 HP
Best Samsung DVM S Heat recovery Outdoor AC Unit - World Top Energy efficiency AC unit Best Samsung DVM S Heat recovery Outdoor AC Unit - World Top Energy efficiency AC unit

World Top Energy Efficiency

Samsung DVM S offers higher energy efficiency and easy to install models that keep your business moving forward.

Best Samsung DVM S Heat recovery Outdoor AC Unit - Easy and flexible design Best Samsung DVM S Heat recovery Outdoor AC Unit - Easy and flexible design

Reduce expenses with installation designed to be easy and flexible

At 22 horsepower (HP), the large-unit capacity of the DVM S facilitates economical installation with a smaller footprint and lighter weight. Non-polar communication between indoor and outdoor units promotes easier wiring work. Non-polar communication is safer because the outdoor unit protects itself if the communication cable is mistakenly connected to a power terminal. The DVM S provides extended piping length of up to 220 m (721.79 ft), with no decrease in performance. With this technology, installation is available for a maximum height of 110 m (360.89 ft), the equivalent of 20 stories. The piping distance is far between outdoor and indoor units, so individual indoor units perform capacity connection control and automatic refrigerant equalization. This process promotes balanced performance between the units.

Samsung DVM S Heat recovery Outdoor AC Unit - High energy efficiency with DSI feature Samsung DVM S Heat recovery Outdoor AC Unit - High energy efficiency with DSI feature

Achieve high energy efficiency with the DSI system

DSI is a third-generation system that uses a Dual Inverter Compressor. The compressor upgrades refrigerant flow and the motor’s operating performance. With this system, DSI achieves high energy efficiency. The two compressors operate in unison so that overall compressor durability is preserved for a longer time. With compressor speed acceleration and simultaneous starting, DVM S provides rapid cooling and heating performance. In addition, DVM S promotes stable, equal oil balancing without the need for an additional balancing pipe.

Samsung DVM S Heat recovery Outdoor AC Unit - 12 hour quiet operation lesser noise Samsung DVM S Heat recovery Outdoor AC Unit - 12 hour quiet operation lesser noise

Lessen disruptions with 12-hour quiet operation

DVM S outdoor fans include an operation control system that drastically reduces noise levels. Quiet operation continues for 12 hours, so users can take advantage of decreased distractions during the night.

Samsung DVM S Heat recovery Outdoor AC Unit - ACM technology feature (auto fix problems) Samsung DVM S Heat recovery Outdoor AC Unit - ACM technology feature (auto fix problems)

Discover and fix problems readily with Auto Commissioning Management (ACM)

DVM S has a smart management system that facilitates self-diagnosis, auto commissioning, auto management and mobile data transmission. DVM S monitors the operation status and displays an error code in response to signs of abnormal operation, enabling users to readily address the problem. If a malfunction occurs with the DVM S outdoor unit, the last 30 minutes of operating data are stored for automatic backup. Small openings on the front of the outdoor unit promote straightforward unit status checking and option setting. With S-Checker, users can control the system with a smartphone or tablet PC, so management is simplified and convenient. ACM promotes reduced commissioning time for DVM S, at just 50 minutes. Testing results are automatically stored and reported.

Specifications

Features

  • Type DVM S (HR)

Model Name

  • Outdoor Unit AM160FXVAGR/EU

Power Supply (Outdoor Unit) [Φ, #, V, Hz]

  • 3,4,380 - 415,50

System

  • Mode HEAT RECOVERY

Performance (nominal)

  • 16HP

Capacity

  • Cooling [kW] 45 
  • Cooling [Btu/h] 153,500 
  • Heating [kW] 50 
  • Heating [Btu/h] 170,600 

Power Input (Nominal)

  • Cooling 1) 11kW
  • Heating 2) 11.5kW

Current Input (Nominal)

  • Cooling 1) 17.6A
  • Heating 2) 18.4A

Power

  • MCA [A] 40 (MCA) 
  • MFA [A] 40 

Energy Efficiency

  • EER (Nominal Cooling) 4.09
  • COP (Nominal Heating) 4.35

Compressor

  • Type SSC Scroll x 2
  • Output(kW) (4.96 x 2) 
  • Model DS-GB052FAVASG x 2
  • Oil (Type) PVE
  • Oil (Initial Charge) [cc] 4000 

Fan

  • Type Propeller
  • Motor (Output) [W] 620 x 2 
  • Air Flow Rate (High / Mid / Low) [CMM] 250 
  • Air Flow Rate(High/Mid/Low)[L/S] 4,333.33
  • External Static Pressure (Min / Std / Max) [mmAq]
  • External Static Pressure (Min / Std / Max) [Pa] 78.45 

Piping Connections

  • Liquid Pipe (Φ, mm) 12.7 
  • Gas Pipe (Φ, mm) 28.58 
  • Discharge Gas Pipe (Φ, mm) 22.22 
  • Installation Max. Length [m] 200 (220) 
  • Installation Max. Height [m] 110 (40) 

Field Wiring

  • Transmission Cable 0.75 ~ 1.5

Refrigerant

  • Type R410A
  • Factory Charging (kg) 7.4 

Sound

  • Sound Pressure 63dBA
  • Sound Power 83dBA

External Dimension (Outdoor Unit)

  • Net Weight 284 
  • Shipping Weight (kg) 303 
  • Net Dimensions (WxHxD) (mm) 1,295 x 1,695 x 765 
  • Shipping Dimensions (WxHxD) (mm) 1,363 x 1,887 x 832 

Operating Temp. Range

  • Cooling (℃) -15 ~ 48 
  • Heating (℃) -20 ~ 24 

Compare the models

Compare with similar items

DVM S, Standard, Heat Recovery R410a, 380~415V, 50Hz, 3Ф, Outdoor Unit

AM160FXVAGR/EU

VRF DVM S2 HEAT PUMP

AM340AXVANH/TL

  • World’s only Wind Free compatible

  • Advanced Flash Injection Compressor

  • Robust Frame

  • Capacity

    95.2 kW

VRF DVM S2 COOLING ONLY

AM340AXVANC/TL

  • World’s only Wind Free compatible

  • Advanced Flash Injection Compressor

  • Robust Frame

  • EER (Nominal Cooling)

    3.00

DVM, 2-Way Cassette, Heat Pump R410a, Indoor Unit

AM071FN2DEH/TL

DVM, Ceiling, Heat Pump R410a, Indoor Unit

AM071FNCDEH/EU

DVM, Slim Duct,R-410A, Indoor unit

AM022FNLDEH/TL

Recently Viewed

8 HP10 HP12 HP14 HP16 HP18 HP20 HP22 HP